Air Data Computers
- Standalone computation provides industry-leading size, weight and power (SWAP), enabling increased fuel performance
- Reduced maintenance costs from periodic accuracy checks due to industry-leading sensor stability
- Our air data products offer industry-leading sensor stability with our silicon pressure sensors and transducers as well as excellent long-term stability for reduced maintenance
Specifications
Performance
Accuracy
- 0.02% FS accuracy
Sensor Range
- 2 in Hg to 41 in Hg (Ps and Pt)
Number of Sensors/Channels
- 2
Key Benefits
- Extensive Field History with long service life
- Low cost modular design optimized for both new build and retrofit applications
- Proven solid-state silicon sensor technology provides long-term stability
Coverage
- 98% BIT coverage meter
Altitude Range
- -2,000 to +60,000 ft
Physical
Weight
- 4.5 lbs. max (w/o fittings)
Dimensions
- 1489 mm Length x 158 mm Width x 107 mm Height
- 5.9 in. Length x 6.2 in Width x 4.2 in Height
Connectivity and Systems
Software
- RTCA/DO-178B Level A
Output
- ARINC 429
- All necessary air data parameters, Maintenance Data
- Analog and Discrete Outputs ADT Valid
Digital Communication Output
- All Necessary Air Data Parameters (ARINC 429)
- Maintenance Data (ARINC 429)
Digital Communication Input
- ARINC 429
- ASCB
- Digital Baro Correction
Power and Electrical
Power
- 28 VDC, less than 15.5 Watt Watt
Environmental
Environment
- D0-160 D
Mechanical
Chassis Included
- Yes
Certification
Certifications
- TSO-C106